Locate buildings out of flood-prone areas
Rationale: Locating facilities out of flood-prone zones and managing for potential flood risks decreases the immediate risk of mortality, injury, and PTSD from flooding and mitigates the longer-term risk of degraded indoor air quality from water damage, which is linked to chronic respiratory conditions and contagious diseases.
For the most accurate strategy and documentation requirements, please refer to the digital scorecard made available on the Fitwel Platform.
Requirements
Demonstrate compliance with one of the options below:
Option 1 - Flood-Prone Areas (Full Credit):
Demonstrate compliance with all the following requirements:
Low-Rise Residential with shared interior spaces (LR+), Low-Rise Residential with no shared interior spaces (LR)
- Identify the flood risks within the project according to local flood risk maps.
Locate all buildings within the project outside of flood-prone areas*.
*Flood-prone areas are those that are likely to flood over the next 30 years (> 6% chance of 1 inch of water reaching the largest home or building on a property at least once during this time period).
*Flood-prone areas are those that are at risk of coastal flooding, heavy rains, and poor drainage.
Option 2 - Flood-Risk Mitigation (Full Credit):
The project may achieve partial credit by demonstrating compliance with all of the following requirements:
Low-Rise Residential with shared interior spaces (LR+), Low-Rise Residential with no shared interior spaces (LR)
- Identify the flood risks according to local flood risk maps within the project.
- Implement a minimum of two of the following qualifying flood-risk mitigation practices for each building within the project:
- elevate boilers so they are not located at or below ground level
- install a sewage water backstop
- improve lot grading so that stormwater runs away from the building by building up any sunken areas around the foundation or digging small depressions to properly channel water
- integrate stormwater management strategies into landscaping through rain gardens, vegetated swales, or pervious pavements
- install a rain barrel
- develop a maintenance plan for gutters, downspouts, and splash pads so that rainwater from the roof flows easily away from the building
- anchor outdoor fuel tanks
- elevate utilities and service equipment so that they are a minimum of 1 foot above the flood elevation.
Compliance Documentation
Design Pathway (LR+, LR)
Option 1:
- Requirement 1:
- Upload an annotated site plan or map identifying the flood risk areas within the project.
- Requirement 2:
- Upload an annotated site plan or map identifying the planned location of the buildings within the project.
Option 2:
- Requirement 1:
- Upload an annotated site plan or map identifying the flood risk areas within the project.
- Requirement 2:
- Upload a description of the flood-risk mitigation practices that will be implemented.
- Checkbox to certify that the below flood-risk mitigation practices will be implemented (minimum two):
- elevate broilers so they are not located at or below ground level
- install a sewage water backstop
- improve lot grading so that stormwater runs away from the building by building up any sunken areas around the foundation or digging small depressions to properly channel water
integrate stormwater management strategies into landscaping through rain gardens, vegetated swales, or pervious pavements - install a rain barrel
- develop a maintenance plan for gutters, downspouts, and splash pads so that rainwater from your roof flows easily away from your home
- anchor outdoor fuel tanks
- elevate utilities and service equipment so that they are a minimum of 1 foot above the flood elevation.
- Upload an annotated design drawing(s) or product specification sheet(s) of each unique planned flood-risk mitigation practice that will be implemented within the project.
- Upload annotated design drawings or plans showing the location of each unique planned flood-risk mitigation practice that will be implemented within the project.
Built Pathway (LR+, LR)
Option 1:
- Requirement 1:
- Upload an annotated site plan or map identifying the flood risk areas within the project.
- Requirement 2:
- Upload an annotated site plan or map identifying the location of the buildings within the project.
Option 2:
- Requirement 1:
- Upload an annotated site plan or map identifying the flood risk areas within the project.
- Requirement 2:
- Upload a description of the flood-risk mitigation practices that are implemented.
- Checkbox to certify that the below flood-risk mitigation practices are implemented (minimum two):
- elevate broilers so they are not located at or below ground level
- install a sewage water backstop
- improve lot grading so that stormwater runs away from the building by building up any sunken areas around the foundation or digging small depressions to properly channel water
integrate stormwater management strategies into landscaping through rain gardens, vegetated swales, or pervious pavements - install a rain barrel
- develop a maintenance plan for gutters, downspouts, and splash pads so that rainwater from your roof flows easily away from your home
- anchor outdoor fuel tanks
- elevate utilities and service equipment so that they are a minimum of 1 foot above the flood elevation.
- Upload an annotated photograph(s) of each unique planned flood-risk mitigation practice implemented within the project.
- Upload annotated plan(s) showing the location of each unique flood-risk mitigation practice that implemented within the project.
Comments
0 comments
Please sign in to leave a comment.