Provide a universally accessible site
Rationale: Implementing universal accessibility practices that support those with a broad range of abilities across a site ensures that all people are able to move freely between spaces and comfortably use facilities, contributing to increased physical activity, enhanced social inclusion, and decreased the risk of injury and psychological distress.
For the most accurate strategy and documentation requirements, please refer to the digital scorecard made available on the Fitwel Platform.
Requirements
Demonstrate compliance with the below:
Universally Accessible Site (Full Credit):
Demonstrate compliance with all of the following requirements:
Multi-Tenant Retail, Retail
- Provide adjoining ramps and sloped access for all outdoor stairs or steps leading to a main entrance to the building(s), including direct access entrance(s) to the building(s) from parking garages.
- Provide an automatic or push button door at a main building(s) entrance.
- Ensure threshold height and configurations are flush with external and internal ground surfaces at each main entrance to the building(s), including direct access entrance(s) to the building(s) from parking garages.
- Provide tactile direction indicators leading to a main building(s) entrance(s).
- Ensure that all on-site outdoor stair surfaces within the building(s) site meet one of the following:
-
- are coated with non-slip material.
- include tactile material at each step to indicate a change in level.
-
- Ensure an accessible route(s) to all on-site parking areas that is free of obstacles such as impeding trees, planting pots, bollards, bike racks, steps, uncovered/non-accessible drain grates or other barriers that may impede or cause difficulties for those with physical disabilities.
Compliance Documentation
Design Pathway
MTR, RT
Requirement 1
-
-
Upload an annotated site plan or map(s) identifying the following:
-
-
-
the planned location of all main building entrances
- the planned location of all direct access building entrances from parking garages.
-
the planned location of all outdoor stairs along pathways leading to building entrances
-
the planned location of all outdoor ramps along pathways leading to building entrances
-
-
-
-
Upload annotated design drawings or a photograph(s) of each unique accessible entrance
-
Requirement 2
-
Upload annotated design drawings or a photograph(s) of each unique entryway with automatic or push button doors showing the automated feature.
Requirement 3
-
-
Upload annotated design drawings or a photograph(s) of each unique entryway with flush threshold showing the external and internal ground surfaces.
-
Requirement 4
-
-
Upload annotated design drawings or a photograph(s) showing the tactile direction indicators leading to a main building(s) entrance(s).
-
Requirement 5
- Upload an annotated site plan or map(s) identifying all planned outdoor stairs within the building site.
- Upload annotated design drawings or a photograph(s) of each unique outdoor stair.
Requirement 6
- Upload annotated design drawings or a photograph(s) showing the accessible route(s) to each on-site parking area.
Built Pathway
MTR, RT
Requirement 1
-
-
Upload an annotated site plan or map(s) identifying the following:
-
-
-
the location of all main building entrances
- the location of all direct access building entrances from parking garages.
-
the location of all outdoor stairs along pathways leading to building entrances
-
the location of all outdoor ramps along pathways leading to building entrances
-
-
-
-
Upload annotated design drawings or a photograph(s) of each unique accessible entrance
-
Requirement 2
-
Upload an annotated photograph(s) of each unique entryway with automatic or push button doors showing the automated feature.
Requirement 3
-
-
Upload annotated design drawings or a photograph(s) of each unique entryway with flush threshold showing the external and internal ground surfaces.
-
Requirement 4
-
-
Upload an annotated photograph(s) showing the tactile direction indicators leading to a main building(s) entrance(s).
-
Requirement 5
- Upload an annotated site plan or map(s) identifying all outdoor stairs within the building site.
- Upload annotated design drawings or a photograph(s) of each unique outdoor stair.
Requirement 6
- Upload annotated design drawings or a photograph(s) showing the accessible route(s) to each on-site parking area.