Please note, the below requirements and compliance documentation will be updated soon to reflect v3 changes. You can find more information on these revisions in a Change Log that will be available on the Help Center on December 10, 2024. ________________________________________________________________________
Implement acoustic control measures to minimize interior-sourced noises
Rationale: Acoustic control measures that minimize unwanted interior-sourced noise — such as installing silencers in HVAC ducts and sealing interior-facing doors — can support improved cognitive function and sleep and prevent associated health issues such as hearing loss, accidents, and cardiovascular disease.
For the most accurate strategy and documentation requirements, please refer to the digital scorecard made available on the Fitwel Platform.
Requirements
Demonstrate compliance with the below:
Option 1 - Interior Acoustic Control Measures (Full Credit):
Demonstrate compliance with the following requirements:
Multi-Tenant Whole Building (no on-site management), Multi-Tenant Whole Building (with on-site management)
- Implement a minimum of two of the following interior acoustic control measures throughout the building(s) to limit interior-sourced noises caused by other occupants, appliances, renovations, busy indoor common areas, and other interior sources:
- using sound and vibration-absorption materials such as fiberglass thermal insulation
- sealing interior-facing doors
- adding acoustic panels to all floors and ceiling
- installing silencers in HVAC duct lines.
Single-Tenant
- Implement a minimum of two of the following interior acoustic control measures throughout the building(s) to limit interior-sourced noises caused by other occupants, appliances, renovations, busy indoor common areas, and other interior sources:
- using sound and vibration-absorption materials such as fiberglass thermal insulation
- sealing interior-facing doors
- adding acoustic panels to all floors and ceiling
- installing silencers in HVAC duct lines.
Commercial Interior
- Implement a minimum of two of the following interior acoustic control measures throughout regularly occupied spaces accessible to tenant occupants within the building(s) to limit interior-sourced noises caused by other occupants, appliances, renovations, busy indoor common areas, and other interior sources:
- using sound and vibration-absorption materials such as fiberglass thermal insulation
- sealing interior-facing doors
- adding acoustic panels to all floors and ceiling
- installing silencers in HVAC duct lines.
Option 2 - Sound Transmissing Class (STC) Rating - (Full Credit):
Demonstrate compliance with the following requirements:
Multi-Tenant Whole Building (no on-site management), Multi-Tenant Whole Building (with on-site management)
- Confirm the building(s) meets all of the following Sound Transmission Class (STC) ratings:
– all interior wall construction materials are at least STC 60
– floor construction materials are at least STC 60
Single-Tenant, Commercial Interior
- Confirm the building(s) meets all of the following Sound Transmission Class (STC) ratings:
– all interior wall construction materials are at least STC 60
– floor construction materials are at least STC 60
Compliance Documentation
Design Pathway
Option 1:
-
Checkboxes to certify that the building(s) will include a minimum of two of the listed acoustic control measures
-
Upload annotated design drawings detailing:
-
the location of each acoustic control measure within the building(s)
-
the proposed acoustic control measures within the building(s)
-
Option 2:
-
Text boxes to input the planned STC rating of all of the following:
-
Interior wall construction materials
-
Floor construction materials
-
- Upload an annotated design drawing or spec sheet identifying the STC rating of at least 60 for all construction materials for all required walls and floors
Built Pathway
Option 1:
-
Checkboxes to certify that the building(s) includes a minimum of two of the listed acoustic control measures
-
Upload annotated photographs or specifications showing:
-
the location of each acoustic control measure within the building(s)
-
each acoustic control measure implemented within the building(s)
-
Option 2:
-
Text boxes to input the STC rating of all of the following:
-
interior wall construction materials
-
floor construction materials
-
- Upload an annotated map or site plan identifying the interior walls and floors that have an STC of at least 60